Applications //
This sheet is typically used to provide a pathway to dissipate static charge and prevent flash over.
Technical Data//
| |
| TYPICAL VALUES |
1090 |
METHOD |
| SPECIFIC GRAVITY |
1.6 |
ASTM D792 |
| IZOD IMPACT STRENGTH ( NOTCH ) |
>9.5 ft-lb/in. |
ASTM D256 |
| COMP. STRENGTH (PSI) |
30,000 |
ASTM D790 |
| FLEXURAL STRENGTH (PSI) |
25,000
|
ASTM D790
|
| TENSILE STRENGTH (PSI) |
16,500 |
ASTM D635 |
| SHEAR STRENGTH (PSI) |
9,000 |
ASTM D732 |
| FLEXURAL MODULUS (PSI) |
0.9 X 106 |
ASTM D790 |
| TENSILE MODULUS (PSI) |
1.0 X 106 |
ASTM D635 |
| SURFACE RESISTIVITY (Ohms/Sq.) |
500 to 1300 |
ASTM D257 |
| WATER ABSORBTION % - 24hrs @ 23°C |
<0.5% |
ASTM D570 |
The property values shown are based upon tests on 1/8" thick laminates and believed to be reliable.
|